HVDC generator

HVDC generator

DC high voltage test system uses AC voltage multiplication and rectification. Selection of capacitor and number of stage is significant to the performance of DC generator.

HV silicone stack uses hydraulic pressure for polarity changeover. It can be realized quickly by control system in long-distance.

Grounding switch quickly & effectively releases the residual charge.

SCR automatic tracking function keeps the voltage of test object stable.


DC high voltage test system uses AC voltage multiplication and rectification. Selection of capacitor and number of stage is significant to the performance of DC generator.

HV silicone stack uses hydraulic pressure for polarity changeover. It can be realized quickly by control system in long-distance.

Grounding switch quickly & effectively releases the residual charge.

SCR automatic tracking function keeps the voltage of test object stable.


DC high voltage test system:

It is used for DC voltage withstanding test for power cable, DC pollution, thyristor valve set, generator and switch, etc.; also for DC voltage withstanding and polarity changeover test for DC extra-high voltage power equipment; testing the characteristic of all kinds of insulation material under DC high voltage; detecting DC discharge property of air gap; measuring leakage current and discharge test for insulator (string); testing of corona starting voltage of wires, metal and insulator.


DC pollution test system needs special design:

DC power main loop is composed of test transformer, multiplying and rectifying circuit, etc. The power source for primary coil of test transformer is provided by voltage regulator through SCR automatic tracking device, and the control system monitors the voltages at HV terminals and the value of leakage current of test object, tracking the changes of voltage and current. Finally use the fuzzy control algorithm to achieve close-loop double feedback dynamic voltage regulation. The system control algorithm is concise and control is with high accuracy and fast reaction which makes the dynamic over-shoot and voltage drop value for HV output always within the limits.

The main parameters meets the requirement of IEC-61245 DC Artificial Pollution Test, that is, the relative voltage drop is not more than 10% during the test (leakage current can be more than 1A in heavy pollution); the relative voltage overshoot is not more than 10%; the voltage drop of test object is less than 5% and the voltage overshoot is less than 8% under resistive load current lasting for 0.5s and the output current is 500mA.

Equipment is mainly used for DC pollution test and icing test of insulator strings and post insulator used in DC transmission project at various altitudes.


Parameter


Project
1600kV 2A DC High Voltage Test System for China Power Electric Research Institute
1000kV 2A DC Pollution Test System for Kuming EHV Test Base of South Power Grid (China)
1000kV 30mA HVDC outdoor
800kV 20mA HVDC outdoor
1200kV 30mA DC Test System for Fulgor Hellenic Cables
1200kV 30mA DC High Voltage Test System for SECRI, China
800kV 500mA Outdoor Three phases HVDC Test System
1000kV 20mA DC Test System for Hunan Changsha Cable Accessories Co. LTD
1000kV 20mA DC Test System for Hunan Changsha Cable Accessories Co. LTD
800kV 20mA DC High Voltage Test System for Nexans Cable
800kV 20mA DC Generator for Qingdao Hanhe cable
800kV 10mA DC Generator for Shanghai Electric Cable Research Institute
Date Sheets

DC High Voltage Test System.pdf